Lux (symbol lx) is the SI unit of illuminance. It measures how much light falls on a surface: one lux is one lumen spread over one square metre. Lux is the Latin word for light, so it has no full form.
The four facts most people are looking for
The unit for light arriving on a surface
Lux (symbol: lx) is the unit of illuminance. It tells you how much light reaches a desk, a floor or a wall, which is what matters for seeing a task. It does not tell you how much light a lamp gives out; that is measured in lumens.
A lamp giving 1,000 lumens spread evenly over 10 square metres produces 100 lux. Spread over 2 square metres, the same lamp produces 500 lux.
Lux falls quickly with distance. Double the distance from a small light source and the lux drops to about a quarter, which is why the same fitting gives very different readings at desk height and at floor level.
Typical lux levels, from direct sun down to moonlight
Outdoor figures are typical published values and vary with season, time of day and weather.
The maintained lux levels UK lighting is normally checked against
| Area or task | Lux level | Standard | Full guide |
|---|---|---|---|
| Office desk work | 500 lux | BS EN 12464-1 | Office lux levels |
| Technical drawing | 750 lux | BS EN 12464-1 | Office lux levels |
| Classroom | 500 lux | BS EN 12464-1:2021 | School lux levels |
| Shop sales floor | 300 lux, 500 at tills | BS EN 12464-1 | Retail lux levels |
| Hospital ward | 100 lux, 300 for reading | BS EN 12464-1 | Hospital lux levels |
| Corridors and stairs | 100 lux | BS EN 12464-1 | Corridor lux levels |
| Warehouse storage | 100 lux, 300 for packing | BS EN 12464-1 | Warehouse lux levels |
| Emergency escape route | 1 lux minimum | BS EN 1838 | Emergency light testing |
UK law does not set lux figures. Regulation 8 of the Workplace (Health, Safety and Welfare) Regulations 1992 requires every workplace to have suitable and sufficient lighting. BS EN 12464-1 is the benchmark normally used to show that lighting is suitable, and recorded measurements are the evidence.
Much lower figures than normal lighting, measured with the normal lighting off
The levels come from BS EN 1838. BS 5266-1 covers testing: a short functional test of every luminaire each month, a full-duration test each year, and every test recorded in the logbook. Duration is 1 to 3 hours depending on the premises, and 3 hours where people sleep. See emergency light testing for the routine and the certificates.
Lux level testing that gives readings you can rely on
A room can meet its average and still have dark patches. Divide the lowest reading by the average to get the uniformity. BS EN 12464-1 sets a minimum for each task, for example 0.60 for office desk work and 0.40 for circulation areas.
Dedicated lux meters are classified by accuracy under BS 667 in the UK and ISO/CIE 19476 internationally. A phone is not a classified instrument, so phone readings suit spot checks, before-and-after comparisons and records. For formal verification of a new installation, use a calibrated meter and record its calibration date.
Common questions about what lux means and how it is measured
Lux has no full form. It is not an abbreviation but the Latin word for light, adopted as the name of the SI unit of illuminance. Its symbol is lx.
Lux is the amount of light falling on a surface. One lux is one lumen per square metre, so a lux level tells you how brightly a desk, floor or wall is lit, not how much light the lamp gives out.
Lumens measure the total light a lamp gives out. Lux measures how much of that light lands on a surface. The same lamp gives a high lux level on a small area close by and a low lux level on a large area further away.
BS EN 12464-1 sets 500 lux on the desk for reading, writing and screen work. Circulation areas and corridors need 100 lux.
One foot-candle is 10.76 lux. Divide a lux reading by 10.76 to get foot-candles, or multiply foot-candles by 10.76 to get lux.
Yes. BS 667 covers illuminance meters in the UK and ISO/CIE 19476 does so internationally, and both classify meters by accuracy. A phone is not a classified instrument, so formal verification of a new installation is done with a calibrated meter.
Modern smartphones can achieve plus or minus 10-15% accuracy when properly calibrated. That suits spot checks, before-and-after comparisons and keeping records. For formal verification, use a calibrated meter and record its calibration date.
Measure when lighting is installed or a space is first occupied, after any change to the lighting or layout, and when people report a problem. An annual check is a sensible routine for most workplaces.
Daylight, lamp ageing, dirt on fittings, the colour of walls and ceilings, ceiling height and where the fittings are. Readings also change with the height and angle of the meter, so measure at the task and keep your shadow off the sensor.
There is no legal figure for a home, but the workplace level is a good guide: about 500 lux on the desk and 300 lux in the rest of the room.