Parking Garage Lighting Lux Levels UK - Complete BS EN 12464-2 Security Guide

Professional guide to UK parking garage lighting requirements per BS EN 12464-2.Traffic routes (75 lux), parking areas (20 lux), pedestrian zones (50 lux), and security lighting. Essential compliance information for car park operators and security professionals.

📋 BS EN 12464-2 Outdoor
🚗 Car Park Standards
🇬🇧 UK Requirements
🔒 Security Lighting
🚗 UK Parking Garage Requirements
Traffic Routes
75 lux
Vehicle lanes, ramps
Parking Areas
20 lux
Vehicle bays, general parking
Pedestrian Zones
50 lux
Walkways, stairs, lifts
Payment Areas
100 lux
Ticket machines, barriers

All values per BS EN 12464-2

Complete UK Parking Garage Lighting Standards - BS EN 12464-2

Comprehensive breakdown of illuminance requirements for all car park areas and vehicle parking security according to British Standards

Parking Area/Zone Required Lux Level Standard Reference Application Notes Uniformity Ratio
Traffic Routes 75 lux BS EN 12464-2:2014 Vehicle lanes, ramps, main circulation routes ≥ 0.4
Parking Areas 20 lux BS EN 12464-2:2014 General parking bays, vehicle storage areas ≥ 0.25
Pedestrian Walkways 50 lux BS EN 12464-2:2014 Footpaths, pedestrian circulation areas ≥ 0.4
Payment/Ticket Areas 100 lux BS EN 12464-2:2014 Ticket machines, payment kiosks, barriers ≥ 0.5
Stairwells in Car Parks 150 lux BS EN 12464-1:2021 Level changes, pedestrian stairs ≥ 0.5
Lift Areas 100 lux BS EN 12464-2:2014 Lift lobbies, waiting areas ≥ 0.4
Entry/Exit Points 100 lux BS EN 12464-2:2014 Vehicle entry/exit, security checkpoints ≥ 0.4
Security/CCTV Areas 50 lux BS EN 12464-2:2014 Surveillance coverage, crime prevention ≥ 0.25
Disabled Parking Bays 50 lux BS EN 12464-2:2014 Accessible parking, mobility aid areas ≥ 0.4
Emergency Assembly Points 5 lux BS 5266-1:2016 Emergency evacuation areas, safety zones ≥ 0.25
Underground Car Parks 20 lux BS EN 12464-2:2014 Enclosed parking areas, basement levels ≥ 0.25
Multi-Storey Ramps 75 lux BS EN 12464-2:2014 Spiral ramps, level transitions ≥ 0.4

Lighting Requirements for Different Car Park Types

Specialized lighting considerations for various parking facility types and user demographics

Shopping
50-100 lux

Retail Car Parks

Enhanced lighting for customer comfort and safety. Higher levels (75-100 lux) create welcoming environment and improve security perception for shoppers carrying purchases.

Office
20-75 lux

Commercial Buildings

Standard compliance levels with enhanced lighting near building entrances. Consider employee safety during early/late hours and seasonal daylight variations.

Residential
20-50 lux

Housing Developments

Minimum compliance levels balanced with light pollution concerns.Focus on safety at pedestrian routes and visitor parking areas near residential buildings.

Hospital
50-100 lux

Healthcare Facilities

Higher illuminance for vulnerable users and emergency access. 24/7 operation requires consistent lighting with backup systems for critical patient areas.

Airport
75-150 lux

Transport Hubs

Enhanced security lighting for international facilities. Long-term parking requires excellent coverage and wayfinding systems for passenger orientation.

Multi-Storey
20-100 lux

Underground/Enclosed

Artificial lighting only with emergency backup systems.Enhanced lighting at level transitions, stairwells, and lift areas for enclosed environment safety.

Car Park Lighting Design Principles

🔒 Security Focus

Eliminate dark spots and hiding places that could compromise security. Ensure CCTV coverage areas have adequate illumination for effective surveillance.

🚗 Vehicle Navigation

Provide clear illumination of traffic routes, signage, and level markers. Help drivers navigate safely through the car park layout.

🚶 Pedestrian Safety

Enhanced lighting for walkways, stairs, and building connections.Ensure safe passage from vehicles to destinations with clear sightlines.

Security Lighting Considerations for Car Parks

Crime prevention and personal safety measures through effective lighting design and coverage

📹

CCTV Integration

Coordinate lighting with surveillance systems. Ensure camera coverage areas have adequate illumination (minimum 50 lux) for clear image quality and facial recognition.

👁️

Eliminate Blind Spots

Remove dark areas where criminal activity could occur undetected.Pay special attention to corners, pillars, stairwells, and areas behind large vehicles.

🚨

Emergency Points

Enhance lighting at emergency call points, fire exits, and assembly areas.Ensure these safety features are clearly visible and accessible at all times.

24/7 Operation

Maintain consistent security lighting throughout night hours.Use smart controls to optimize energy while ensuring minimum safety levels are never compromised.

🚪

Entry/Exit Security

Enhanced illumination at vehicle and pedestrian entry points.Critical for barrier operation, security checks, and license plate recognition systems.

👥

Personal Safety

Higher lighting levels in vulnerable areas create perception of safety.Well-lit car parks encourage use and reduce fear, particularly for women and elderly users.

🔋

Backup Systems

Emergency lighting ensures security during power outages. Critical for enclosed car parks where natural light is unavailable during emergencies.

📱

Smart Monitoring

IoT sensors can detect lighting failures and security breaches.Automatic alerts ensure rapid response to maintain continuous security coverage.

Modern Car Park Lighting Technology

Smart lighting solutions and energy-efficient technology for secure, cost-effective parking facilities

💡

LED Parking Luminaires

High-efficacy LED fixtures provide 60-70% energy savings compared to traditional sources. Long life reduces maintenance costs in hard-to-reach car park locations.

📱

Motion Sensors

Occupancy detection provides full lighting when needed while maintaining security base levels.Significant energy savings in low-traffic periods.

🌅

Daylight Controls

Photocells automatically adjust lighting based on natural light levels.Essential for partially covered car parks and areas with skylights.

Emergency Integration

LED emergency lighting integrated with normal systems. Self-testing capabilities ensure compliance with evacuation lighting requirements.

🔋

Solar Solutions

Solar-powered lighting for remote areas and sustainability goals.Hybrid systems combine grid power with solar backup for enhanced reliability.

📊

Performance Analytics

Smart monitoring tracks energy usage, detects failures, and optimizes performance.Predictive maintenance reduces downtime and security vulnerabilities.

How to Measure Parking Garage Lighting Compliance

Professional step-by-step guide to measuring car park illuminance for BS EN 12464-2 vehicle parking security compliance

1

Map Car Park Zones

Identify different parking areas: traffic routes (75 lux), parking bays (20 lux), pedestrian walkways (50 lux), payment areas (100 lux).Mark security-critical zones.

2

Set Ground-Level Measurement

Position lux meter at ground level (0.2m height) to measure illuminance where vehicles and pedestrians operate.Avoid shadows from parked cars during measurement.

3

Follow Vehicle & Pedestrian Routes

Take measurements along typical driving paths and pedestrian walkways.Include entry/exit points, ramps, level changes, and connections to buildings.

4

Test Security Coverage

Measure lighting in CCTV coverage areas, potential hiding spots, and vulnerable locations.Ensure adequate illumination for surveillance effectiveness.

5

Assess Uniformity & Dark Spots

Calculate uniformity ratios and identify areas with inadequate lighting.Check for proper illumination of signage, barriers, and safety features.

6

Generate Security Report

Create comprehensive assessment with car park layout, security analysis, compliance status, and recommendations for facility management.

Professional Car Park Lighting Assessment Tools

Complete toolkit for measuring, calculating, and documenting parking garage lighting compliance for vehicle facility security

📱

Professional Lux Meter

Measure actual car park lighting levels with professional accuracy.iPhone app with instant PDF certificates for vehicle parking security compliance.

Get Lux Meter →
📊

Car Park Calculator

Calculate required lux levels for different parking zones and security requirements for vehicle facility lighting design.

Calculate Now →
📋

Security Reports

Generate professional car park lighting assessment reports with full BS EN 12464-2 vehicle parking security compliance documentation.

View Reports →

Parking Garage Lighting - Frequently Asked Questions

Common questions about UK car park lighting requirements, measurement, and vehicle parking security compliance

What are the UK parking garage lighting lux level requirements?

BS EN 12464-2 requires 75 lux for traffic routes and ramps, 20 lux minimum for parking areas, 50 lux for pedestrian walkways, 100 lux for payment/ticket areas, and 20 lux for security coverage. These are maintained illuminance levels measured at ground level.

How many lux do I need for car park security lighting?

Car park security requires 20 lux minimum according to BS EN 12464-2, with enhanced levels (50-75 lux) recommended for high-risk areas, CCTV coverage zones, and pedestrian routes for optimal security surveillance and personal safety.

What lighting levels are required for underground parking garages?

Underground parking garages require 20 lux minimum for parking areas and 75 lux for traffic routes per BS EN 12464-2.Additional emergency lighting per BS 5266-1 ensures safe evacuation with minimum 1 lux on escape routes.

Do different car park types need different lighting levels?

Yes. Shopping center car parks may use higher levels (50+ lux) for customer comfort and security. Residential parking can use minimum compliance levels. Multi-storey car parks need enhanced stairwell and circulation lighting.

How do I measure parking garage lighting compliance for planning approval?

Use a calibrated lux meter at ground level across different parking zones: traffic routes, parking bays, pedestrian areas, and security points.Document measurements during hours of operation for planning and building control compliance.

Are there penalties for poor car park lighting in the UK?

Poor car park lighting can result in planning enforcement, increased liability for accidents and crime, and affect insurance coverage.Car park operators have duty of care under Occupiers' Liability Acts to provide safe environment for users.

What uniformity ratios are required for car park lighting?

BS EN 12464-2 requires minimum uniformity of 0.25 for parking areas and 0.4 for traffic routes.This prevents dangerous dark spots while allowing reasonable variation across large car park areas.

Can smart controls be used in car park lighting systems?

Yes, motion sensors and dimming systems can reduce energy consumption while maintaining minimum security levels.Emergency lighting must remain fully operational regardless of control systems.

What emergency lighting is required in car parks?

Multi-storey and underground car parks require emergency lighting per BS 5266-1 for safe evacuation.Minimum 1 lux on escape routes with 1-3 hour duration depending on car park type and occupancy.

How often should car park lighting be assessed and maintained?

Initial assessment after installation, then annual reviews for security and compliance.Monthly emergency lighting tests required. LED systems reduce maintenance frequency while improving reliability and security coverage.

Measure Parking Garage Lighting Professionally

Ensure your car park meets BS EN 12464-2 vehicle parking security requirements with our professional lux meter app. Instant measurements, compliance checking, and PDF certificates for parking facilities.

75 lux
Traffic Routes
20 lux
Parking Areas
📋 PDF
Security Certificates
📱 Download Professional Lux Meter

Professional car park lighting assessment • BS EN 12464-2 vehicle parking compliant • Instant PDF reports